Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 140
Filter
1.
Neotrop. ichthyol ; 19(2): e200097, 2021. tab, graf
Article in English | LILACS, VETINDEX | ID: biblio-1279487

ABSTRACT

Although biotelemetry studies bring useful information, tagging is a highly invasive procedure. For this reason, we assess if intracoelomic tagging alters survivorship, weight gain and/or reproductive capacity of a neotropical migratory fish. In August 2016, 60 fish were equally and randomly distributed among 3 treatments: Control (anesthesia), sham surgery (anesthesia and surgery), and true surgery (anesthesia, surgery and tagging). Surveys for weight and tag expulsion were performed periodically from surgery through spawning (November/2016), with a final survey occurring in May/2017. Mortality was higher in true surgery (25% died) and for males. Twenty percent expelled tags, and initial weight loss followed by gain were verified for all treatments. Females of all treatments spawned, and fecundity and fertility were not different. Then, future studies should consider the losses due to death and tag expulsion when defining the sample number. We also encourage further investigations about differences in mortality between sex and weight variation, as well as any other factor that leads to increase in mortality. This is the first study that investigated tagging effects in reproduction of neotropical fishes, and since the methods and tags used are not species-specific, we infer that similar effects could occur in other species.(AU)


Embora estudos de biotelemetria gerem informações úteis, processos de marcação são invasivos. Por isso, avaliamos se a marcação intracelomática altera sobrevivência, ganho de peso e/ou capacidade reprodutiva de um peixe migrador neotropical. Em agosto de 2016, 60 peixes foram distribuídos igualmente e aleatoriamente entre os tratamentos controle (anestesia), cirurgia-falsa (anestesia e cirurgia) e cirurgia-verdadeira (anestesia, cirurgia e marcação). Vistorias para pesagem e observação de expulsão de marcas foram realizadas periodicamente da cirurgia até a desova (novembro/2016), com uma vistoria final em maio/2017. A mortalidade foi maior nos peixes marcados (25% morreram) e entre machos. Vinte por cento expulsaram as marcas e, para todos os tratamentos, foi observado perda de peso inicial com posterior recuperação. Fêmeas de todos os tratamentos desovaram; fecundidade e fertilidade não foram diferentes. Novos estudos devem considerar as perdas de marcas por mortalidade e rejeição na definição do número amostral. Também recomendamos estudos que investiguem a mortalidade diferencial entre sexos e variação de peso, bem como fatores causadores de mortalidade. Este é o primeiro estudo que investigou efeitos da marcação na reprodução de peixes neotropicais e, uma vez que métodos e marcas utilizadas não são espécie-específicos, inferimos que efeitos similares podem ocorrer em outras espécies.(AU)


Subject(s)
Animals , Reproduction , Weight Gain , Characidae/surgery , Characidae/growth & development , Telemetry , Weight Loss , Fishes
2.
Rev. bras. parasitol. vet ; 29(1): e022419, 2020. tab, graf
Article in English | LILACS | ID: biblio-1092691

ABSTRACT

Abstract This study aimed to evaluate the occurrence of diseases transmitted by Amblyomma ovale in 61 dogs monitored for three years through collections of ticks and blood, interviews, telemetry and camera traps in three areas of Serra do Mar State Park, Brazil. Blood samples were used to investigate infection by Rangelia vitalii by real-time TaqMan PCR and Rickettsia parkeri by IIFA. The collected ticks were submitted to conventional PCR to investigate the presence of R. parkeri . These data were compared with the monitoring results and interviews with the owners. Dogs considered as companion presented a risk of infection by R. parkeri strain Mata Atlantica 5.4 times higher than those not considered as companion (p = 0.009). Dogs that had at least one A. ovale collected during the campaigns had a 10 times higher risk of infection by R. parkeri strain Mata Atlantica than those who did not (p = 0.009). One dog positive for R. vitalii by real-time TaqMan PCR was parasitized by A. ovale frequently during monitoring. Sequenced ompaA - positive DNA samples had 100% identity of R. parkeri strain Mata Atlantica clone As106. From the findings, it is urgent to control domestic dogs around rainforests to reduce zoonoses transmission.


Resumo A ocorrência de doenças transmitidas por Amblyomma ovale em 61 cães monitorados por três anos através de coletas de carrapatos, sangue, entrevistas, telemetria e armadilhas fotográficas foi avaliada em três áreas do Parque Estadual da Serra do Mar - SP. Amostras de sangue foram utilizadas para investigação de Rangelia vitalii através de PCR TaqMan em tempo real e Rickettsia parkeri através da RIFI. Carrapatos coletados foram submetidos à PCR convencional para investigação de R. parkeri . Estes dados foram comparados considerando os resultados do monitoramento e entrevistas. Cães de companhia apresentaram risco de infecção pela R. parkeri cepa Mata Atlântica 5,4 vezes maior que os não considerados como de companhia (p = 0,009). Cães que tiveram pelo menos um A. ovale coletado apresentaram risco de infecção por R. parkeri cepa Mata Atlântica 10 vezes maior do que aqueles que não tiveram (p = 0,009). Um cão positivo para R. vitalii através de PCR TaqMan em tempo real foi parasitado por A. ovale durante o monitoramento. Amostras positivas para o gene ompaA possuíam 100% de identidade do clone As106 de R. parkeri cepa de Mata Atlântica. Assim, é urgente o controle de cães na Mata Atlântica para redução dos riscos de zoonoses.


Subject(s)
Animals , Dogs , Rickettsia/isolation & purification , Rickettsia Infections/veterinary , Ixodidae/microbiology , Dog Diseases/epidemiology , Rickettsia/classification , Rickettsia/genetics , Rickettsia Infections/diagnosis , Rickettsia Infections/epidemiology , Telemetry , Brazil/epidemiology , DNA, Bacterial/analysis , Polymerase Chain Reaction , Sequence Analysis, DNA , Fluorescent Antibody Technique, Indirect , Dog Diseases/diagnosis , Dog Diseases/microbiology , Rainforest
3.
Rev. otorrinolaringol. cir. cabeza cuello ; 79(3): 279-289, set. 2019. tab, graf
Article in Spanish | LILACS | ID: biblio-1058698

ABSTRACT

RESUMEN Introducción: La programación adecuada de los implantes cocleares permiten lograr niveles de estimulación auditivos óptimos. Se realiza de forma individualizada, siendo la detección del umbral de confort ideal un desafío. Se ha descrito la utilidad de los potenciales auditivos del tronco encefálico eléctrico (ePEATC) y el reflejo eléctrico estapedial (eREE) para este propósito. Objetivo: Determinar la posibilidad de realizar ePEATC y eREE en pacientes adultos y pediátricos con implantes cocleares, y evaluar cambios en la programación de los implantes cocleares luego de las mediciones objetivas. Material y método: Se realizó un estudio prospectivo, descriptivo, de pacientes con implante coclear marca MED-EL®, separando los pacientes en dos grupos: el grupo adulto (n =5) y el grupo pediátrico (n =5). Todos los pacientes incluidos presentaron más de 6 meses de encendido del implante. Se evaluaron variables epidemiológicas y tiempo de encendido del implante. Se realizó una otoscopía, prueba básica de funcionamiento del implante, y las mediciones objetivas eléctricas (ePEATC, eREE). Con estos resultados se ajustó el umbral de confort. Resultados: El tiempo promedio de encendido del implante en el grupo adulto fue de 27 meses, y 30 meses en el grupo pediátrico. El ePEATC requiere más tiempo y cooperación al compararlo con eREE. Luego de estas evaluaciones objetivas, fue necesario el ajuste del umbral de confort en tres pacientes adultos, y en dos pacientes pediátricos. Fue necesario realizar una audiometría de campo libre para estimar el umbral de confort en dos pacientes pediátricos que no presentaron respuesta en eREE. Conclusión: Fue posible realizar estas mediciones objetivas en pacientes adultos y pediátricos, siendo mejor tolerado y requiriendo menos tiempo, el eREE.


ABSTRACT Introduction: Mapping a cochlear implant allows for adjusting ideal electrical stimulation limits. It is an individualized process and detecting the most comfortable loudness level can be challenging. The use of electrically evoked auditory brainstem response (ePEATC) and electrically evoked stapedius reflex thresholds (eREE) have been considered for this purpose. Aim: To determine the feasibility of performing ePEATC and eREE on adult and pediatric patients with a cochlear implant, and to evaluate changes in programming following these objective measures. Material and method: A prospective, descriptive study was completed, of patients with MED-EL® cochlear implants, separating patients into two groups: adults (n=5) and children (n=5). All of the patients included had their implants activated for 6 months or longer. Epidemiological variables and duration of implant activation were evaluated. Otoscopy, a basic implant functioning evaluation, and objective measures (ePEATC, eREE) were performed. With these results, comfortable loudness levels were adjusted. Results: Average duration of implant activation was 27 months and 30 months, for adults and children respectively. Performing ePEATC required more time and cooperation as compared to eREE. Following the objective measures, adjustment of the comfortable loudness levels was required for three adult and two pediatric patients. Sound field audiometry was necessary for two pediatric patients in order to estimate the comfortable loudness levels because the eREE responses were absent. Conclusions: It is feasible to perform these objective measures for both adult and pediatric patients, with eREE requiring less time and being better tolerated by patients.


Subject(s)
Humans , Male , Female , Child, Preschool , Child , Adult , Middle Aged , Young Adult , Cochlear Implants , Cochlear Implantation/methods , Reflex, Acoustic , Audiometry , Telemetry , Prospective Studies , Evoked Potentials, Auditory, Brain Stem , Health Services Programming
4.
Braz. j. otorhinolaryngol. (Impr.) ; 85(4): 502-509, July-Aug. 2019. tab, graf
Article in English | LILACS | ID: biblio-1019574

ABSTRACT

Abstract Introduction: The conventional evaluation of neural telemetry and impedance requires the use of the computer coupled to an interface, with software that provides visualization of the stimulus and response. Recently, a remote control (CR220®) was launched in the market, that allows the performance of intraoperative tests with minimal instrumentation. Objective: To evaluate the agreement of the impedance values and neural telemetry thresholds, and the time of performance in the conventional procedure and by the remote control. Methods: Multicentric prospective cross-sectional study. Intraoperative evaluations of cochlear implants compatible with the use of CR220® were included. The tests were carried out in the 22 electrodes to compare the time of performance in the two situations. The agreement of the neural telemetry threshold values obtained from five electrodes was analyzed, and the agreement of impedance was evaluated by the number of electrodes with altered values in each procedure. Results: There were no significant difference between the impedance values. There was a moderate to strong correlation between the electrically-evoked compound action potential thresholds. The mean time to perform the procedures using the CR220 was significantly lower than that with the conventional procedure. Conclusion: The use of the CR220 provided successful records for impedance telemetry and automatic neural response telemetry.


Resumo Introdução: A avaliação convencional da telemetria neural e de impedâncias implica o uso do computador acoplado a uma interface, o software fornece o estímulo e a visualização das respostas. Recentemente, foi lançado um controle remoto (CR220®), que possibilita testes intraoperatórios com instrumental mínimo. Objetivo: Avaliar a concordância dos valores das impedâncias e dos limiares da telemetria neural e o tempo de execução no procedimento convencional e pelo controle remoto. Método: Estudo prospectivo transversal multicêntrico. Foram incluídas as avaliações intraoperatórias de implante coclear compatível com o uso do CR220®. Os testes foram realizados nos 22 eletrodos para comparar os tempos de execução nas duas situações. Foi analisada a concordância dos valores do limiar da telemetria neural obtidos em cinco eletrodos e a concordância das impedâncias foi avaliada pelo número de eletrodos com valores alterados em cada procedimento. Resultados: Não houve diferença significante entre as impedâncias. Obteve-se moderada a forte correlação entre os limiares do potencial de ação composto eletricamente evocado. O tempo médio para os procedimentos com o CR220 foi significativamente menor do que com o procedimento convencional. Conclusão: O uso do CR220 proporcionou registros bem-sucedidos para a telemetria de impedância e a telemetria automática de respostas neurais.


Subject(s)
Humans , Child, Preschool , Child , Adolescent , Adult , Middle Aged , Aged , Aged, 80 and over , Young Adult , Telemetry/instrumentation , Cochlear Implants , Cochlear Implantation/instrumentation , Deafness/surgery , Auditory Threshold , Acoustic Impedance Tests , Cross-Sectional Studies , Prospective Studies , Cochlear Implantation/methods , Deafness/etiology , Evoked Potentials, Auditory
5.
Safety and Health at Work ; : 452-460, 2019.
Article in English | WPRIM | ID: wpr-786576

ABSTRACT

BACKGROUND: Monitoring and control of PM(2.5) are being recognized as key to address health issues attributed to PM(2.5). Availability of low-cost PM(2.5) sensors made it possible to introduce a number of portable PM(2.5) monitors based on light scattering to the consumer market at an affordable price. Accuracy of light scattering–based PM(2.5) monitors significantly depends on the method of calibration. Static calibration curve is used as the most popular calibration method for low-cost PM(2.5) sensors particularly because of ease of application. Drawback in this approach is, however, the lack of accuracy.METHODS: This study discussed the calibration of a low-cost PM(2.5)-monitoring device (PMD) to improve the accuracy and reliability for practical use. The proposed method is based on construction of the PM(2.5) sensor network using Message Queuing Telemetry Transport (MQTT) protocol and web query of reference measurement data available at government-authorized PM monitoring station (GAMS) in the republic of Korea. Four machine learning (ML) algorithms such as support vector machine, k-nearest neighbors, random forest, and extreme gradient boosting were used as regression models to calibrate the PMD measurements of PM(2.5). Performance of each ML algorithm was evaluated using stratified K-fold cross-validation, and a linear regression model was used as a reference.RESULTS: Based on the performance of ML algorithms used, regression of the output of the PMD to PM(2.5) concentrations data available from the GAMS through web query was effective. The extreme gradient boosting algorithm showed the best performance with a mean coefficient of determination (R²) of 0.78 and standard error of 5.0 μg/m³, corresponding to 8% increase in R² and 12% decrease in root mean square error in comparison with the linear regression model. Minimum 100 hours of calibration period was found required to calibrate the PMD to its full capacity. Calibration method proposed poses a limitation on the location of the PMD being in the vicinity of the GAMS. As the number of the PMD participating in the sensor network increases, however, calibrated PMDs can be used as reference devices to nearby PMDs that require calibration, forming a calibration chain through MQTT protocol.CONCLUSIONS: Calibration of a low-cost PMD, which is based on construction of PM(2.5) sensor network using MQTT protocol and web query of reference measurement data available at a GAMS, significantly improves the accuracy and reliability of a PMD, thereby making practical use of the low-cost PMD possible.


Subject(s)
Calibration , Forests , Linear Models , Machine Learning , Methods , Particulate Matter , Republic of Korea , Support Vector Machine , Telemetry
6.
Rev. colomb. ortop. traumatol ; 33(S1): 28-33, 2019. ilus.
Article in Spanish | LILACS, COLNAL | ID: biblio-1378915

ABSTRACT

Establecer cuales deformidades angulares en el fémur deben ser tratadas con resección ósea intraarticular inusual más artroplastia total de rodilla en artrosis tricompartimental de rodilla es uno de los retos mayores que se enfrenta en cirugía ortopédica. Presentamos el caso de un paciente masculino de 67 años de edad, con antecedente de fractura diafisaria de fémur hace 30 años tratada en forma conservadora con dolor en la rodilla izquierda de 2 años de evolución con un diagnóstico de artrosis tricompartimental de la rodilla asociada a genu valgum de 20° y consolidación viciosa en diáfisis femoral izquierda con valgo femoral de 10°. El tratamiento quirúrgico realizado fue utilizando cortes intraarticulares inusuales y artroplastia total de rodilla. De acuerdo a la escala propuesta por la Knee Society Score el paciente obtuvo 89 al año de la cirugía. Ante deformidades femorales de hasta 20°, suele ser suficiente realizar la corrección con los cortes óseos intraarticulares (inusuales) evitando afectar las inserciones ligamentarias femorales.


To establish the angular deformities in the femur that should be treated with unusual intra-articular bone resection plus total knee arthroplasty in tricompartmental arthrosis of the knee is one of the major challenges faced in orthopaedic surgery. The case is presented of a 67 year-old male patient with a history of diaphyseal fracture of the left femur (30 years ago) treated conservatively with malunion in left femoral diaphysis with 10° femoral valgus and left knee pain of 2 years onset. He was diagnosed with tricompartmental osteoarthritis of the knee associated with genu valgum of 20°. Surgical treatment was performed using intra articular «unusual¼ bone cuts and total knee arthroplasty. According to the scale proposed by the Knee Society Score, the patient obtained a score of 89 one year after surgery. In femoral deformities of up to 20°, it is usually sufficient to perform the correction with intra articular «unusual¼ bone cuts, and avoiding affecting the femoral ligament insertions.


Subject(s)
Humans , Fractures, Bone , Osteoarthritis , Telemetry , Fractures, Malunited , Genu Valgum
8.
Braz. j. biol ; 78(2): 195-201, May-Aug. 2018. graf
Article in English | LILACS | ID: biblio-888870

ABSTRACT

Abstract The effect of catch-and-release fishing on the survival of peacock bass (Cichla spp.) was evaluated by comparing two types of artificial bait (jig and shallow-diver plugs) and two types of post-catch confinement. Two experiments were conducted during the periods January-February and October-November 2012 in the Unini River, a right-bank tributary of the Negro River. In total, 191 peacock bass were captured. Both groups of fish were subjected to experimental confinement (collective and individual) for three days. Additionally, 11 fish were tagged with radio transmitters for telemetry monitoring. Mortality rate was estimated as the percentage of dead individuals for each type of bait and confinement. For peacock bass caught with jig baits, mortality was zero. The corresponding figure for shallow-diver bait was 1.66% for fish in collective containment, 18.18% for fish monitored by telemetry and 0% for individuals confined individually. Our results show low post-release mortality rates for peacock bass. Furthermore, neither the type of confinement nor the type of bait had a statistically significant influence on mortality rates. While future studies could include other factors in the analysis, our results show that catch-and-release fishing results in low mortality rates.


Resumo O efeito do pesque-solte na sobrevivência do tucunaré (Cichla spp.) foi avaliado comparando dois tipos de iscas artificiais, jig e de meia-água, e dois tipos de confinamento pós-captura. Dois experimentos foram conduzidos durante os períodos de janeiro-fevereiro e outubro-novembro de 2012, no Rio Unini, afluente da margem direita do Rio Negro. No total, 191 tucunarés foram capturados. Os peixes foram submetidos a um confinamento experimental (coletivo e individual) com duração de três dias. Além disso, 11 peixes foram marcados com radiotransmissores e liberados imediatamente após a captura, sendo monitorados por telemetria. A taxa de mortalidade foi calculada como a porcentagem de indivíduos mortos para cada tipo de isca e tratamento (confinamento individual, coletivo e sem confinamento). Não houve mortalidade para o grupo de tucunarés capturados com isca jig. A isca de meia-água mostrou uma taxa de mortalidade de 1,66% para o confinamento coletivo e 18,18% para os peixes monitorados por telemetria. Nossos resultados mostraram baixas taxas de mortalidade pós-soltura para tucunaré. Além disso, nem o tipo de confinamento, nem o tipo de isca tiveram influência significativa nas taxas de mortalidade. Ainda que estudos futuros possam incluir novos fatores na análise, os nossos resultados mostram que a prática do pesque-solte resulta em baixas taxas de mortalidade.


Subject(s)
Animals , Cichlids/physiology , Telemetry , Brazil , Environmental Monitoring , Rivers
9.
Neotrop. ichthyol ; 16(1): e170134, 2018. tab, graf
Article in English | LILACS, VETINDEX | ID: biblio-895127

ABSTRACT

We document movement patterns and home range of Diplomystes camposensis, an endemic and threatened freshwater catfish from Chile. We tracked the movements of seven individuals of different body size (13.5 to 19 cm SL) using portable radio telemetry equipment to investigate movement patterns in relation to day/night activity and habitat use in the San Pedro River (Valdivia Basin). Tracked movements and model-based analyses revealed that D. camposensis has a large home range and high mobility. The average home range was 0.068163 ± 0.033313 km2, and the average area of higher activity was 0.005646 ± 0.011386 km2. The mean linear home range was 387.4 m. The results also showed that movements were longer during the night, supporting nocturnal habits. Movements tended to be in an upstream direction for some individuals, although these differences were not significant when data was pooled. Large home range and movements suggest that the species may require large river areas to meet ecological demands, an aspect that could be severely affected by fragmentation. These results, along with previously published genetic data, suggest that the conservation of D. camposensis would be seriously threatened by hydromorphological alterations (e.g. lack of connectivity), such as those resulting from dam building.(AU)


En este trabajo documentamos patrones de movimiento y estimación de ámbito de hogar de Diplomystes camposensis, un siluriforme endémico y amenazado del Sur de Chile. Por medio de radio telemetría, se monitorearon 7 individuos con un rango de tamaño entre 13.5 y 19 cm de longitud estándar, para evaluar patrones de movimiento con respecto al uso de hábitat y tiempo de actividad (dia/noche) en la zona del Río San Pedro, Cuenca del Río Valdivia. Los resultados muestran que D. camposensis tiene un ámbito de hogar grande y una alta movilidad. El ámbito de hogar fue de 0.068163 ± 0.033313 km2 con un área promedio de mayor actividad de 0.005646 ± 0.011386 km2. El ámbito de hogar lineal medio fue de 387.4 m. Los resultados también mostraron que la especie presenta una mayor actividad por la noche y una tendencia hacia un mayor flujo de movimiento en dirección aguas arriba, aunque esto último no fue significativo. Un ámbito de hogar grande y su alta movilidad sugieren que la especie podría requerir de amplias zonas del río para satisfacer sus demandas ecológicas. Al igual que estudos previos con datos genéticos, estos resultados sugieren que la especie D. camposensis se vería perjudicada por alteraciones en la hidromorfología del cauce (e.g. falta de conectividad) tales como aquellas que resulten de la construcción de represas.(AU)


Subject(s)
Animals , Catfishes/growth & development , Endangered Species/trends , Telemetry/veterinary , Ecosystem
10.
Korean Journal of Otolaryngology - Head and Neck Surgery ; : 527-530, 2017.
Article in Korean | WPRIM | ID: wpr-648840

ABSTRACT

Less traumatic electrode insertion along the basal turn of cochlea is essential to cochlear implantation. However, immoderate attempts to insert the electrode beyond the point of resistance can result in electrode kinking within the basal turn of cochlea. Electrode kinking tends to occur 1) in the use of contour or hugging type of electrode, 2) in the cochlear ossification or fibrosis, and 3) in wrong angle insertion in the approach of round window membrane or cochleostomy near the round window. Intra-operative radiologic evaluation and intra-operative measurement of the neural response telemetry or auditory nerve response telemetry during cochlear implantation is essential to check the status and proper insertion of electrode. Recently, we experienced two cases of electrode kinking in cochlear implantation and discovered that both patients showed abnormal impedances and crumpled electrode in X-ray. Based on these cases, we suggest routine impedance and radiologic measurement during the cochlear implantation.


Subject(s)
Humans , Cochlea , Cochlear Implantation , Cochlear Implants , Cochlear Nerve , Electric Impedance , Electrodes , Fibrosis , Membranes , Telemetry
11.
Philippine Journal of Internal Medicine ; : 1-4, 2017.
Article in English | WPRIM | ID: wpr-633447

ABSTRACT

BACKGROUND: Patients with acute ischemic stroke are susceptible  to  cardiac  arrhythmias  however,fatal arrhythmias  are  rare  in  the  absence  of  cardiac  disease.Cardiac arrhythmias can develop in lesions at the right side of the brain specifically the insular,frontal and parietal area.Data that show the direct relationship of ischemic stroke and arrhythmia are scarce but they are indirectly attributed to an imbalance in the autonomic nervous system.This paper aims to present a rare case of an association between a fatal arrhythmia and right thalamic infarct.   CASE: Presenting a case of a 39-year-old admitted as a survivor of sudden cardiac death from ventricular fibrillation.She presented with a history of left sided weakness a week prior but no work-up was done. Baseline serum electrolytes and  cardiac markers were all normal.Electrocardiogram (ECG) post-cardioversion showed sinus tachycardia.Echocardiogram   and cardiac computed tomography (CT) angiography were normal.  Magnetic resonance imaging (MRI) and angiography (MRA) of the brain showed an acute infarct at the right thalamus and an absent left internal carotid artery (ICA).Electroencephalogram (EEG) was negative.Bisoprolol was given and an Automatic Implantable Cardioverter Defibrillator (AICD) was subsequently placed.No recurrence of cardiac arrhythmia was noted on continuous cardiac telemetry monitoring during her hospitalization and on six months of follow-up.CONCLUSION: Fatal cardiac arrhythmias, can occur in patients with  acute  thalamic  infarct  even  beyond  24  hours  in  the presence of other confounding factors despite the absence of cardiac pathology. This case showed the association of heightened  autonomic  imbalance  caused  by  an  acute stroke, decreased cerebral flow, and fatal arrhythmia. This elucidates the importance of cardiac monitoring in acute ischemic stroke. With the paucity of information on serious cardiac arrhythmia and ischemic stroke, a future study on this correlation will be useful.


Subject(s)
Humans , Female , Adult , Bisoprolol , Tachycardia, Sinus , Ventricular Fibrillation , Carotid Artery, Internal , Defibrillators, Implantable , Electric Countershock , Arrhythmias, Cardiac , Electrocardiography , Death, Sudden, Cardiac , Heart Conduction System , Stroke , Thalamus , Brain , Autonomic Nervous System , Telemetry , Angiography , Hospitalization , Survivors , Electrolytes
12.
Philippine Journal of Internal Medicine ; : 1-4, 2017.
Article in English | WPRIM | ID: wpr-960119

ABSTRACT

@#<p style="text-align: justify;"><strong>BACKGROUND:</strong> Patients with acute ischemic stroke are susceptible  to  cardiac  arrhythmias  however,fatal arrhythmias  are  rare  in  the  absence  of  cardiac  disease.Cardiac arrhythmias can develop in lesions at the right side of the brain specifically the insular,frontal and parietal area.Data that show the direct relationship of ischemic stroke and arrhythmia are scarce but they are indirectly attributed to an imbalance in the autonomic nervous system.This paper aims to present a rare case of an association between a fatal arrhythmia and right thalamic infarct.   <br /><strong>CASE:</strong> Presenting a case of a 39-year-old admitted as a survivor of sudden cardiac death from ventricular fibrillation.She presented with a history of left sided weakness a week prior but no work-up was done. Baseline serum electrolytes and  cardiac markers were all normal.Electrocardiogram (ECG) post-cardioversion showed sinus tachycardia.Echocardiogram   and cardiac computed tomography (CT) angiography were normal.  Magnetic resonance imaging (MRI) and angiography (MRA) of the brain showed an acute infarct at the right thalamus and an absent left internal carotid artery (ICA).Electroencephalogram (EEG) was negative.Bisoprolol was given and an Automatic Implantable Cardioverter Defibrillator (AICD) was subsequently placed.No recurrence of cardiac arrhythmia was noted on continuous cardiac telemetry monitoring during her hospitalization and on six months of follow-up.<br /><strong>CONCLUSION:</strong> Fatal cardiac arrhythmias, can occur in patients with  acute  thalamic  infarct  even  beyond  24  hours  in  the presence of other confounding factors despite the absence of cardiac pathology. This case showed the association of heightened  autonomic  imbalance  caused  by  an  acute stroke, decreased cerebral flow, and fatal arrhythmia. This elucidates the importance of cardiac monitoring in acute ischemic stroke. With the paucity of information on serious cardiac arrhythmia and ischemic stroke, a future study on this correlation will be useful.</p>


Subject(s)
Humans , Female , Adult , Bisoprolol , Tachycardia, Sinus , Ventricular Fibrillation , Carotid Artery, Internal , Defibrillators, Implantable , Electric Countershock , Arrhythmias, Cardiac , Electrocardiography , Death, Sudden, Cardiac , Heart Conduction System , Stroke , Thalamus , Brain , Autonomic Nervous System , Telemetry , Angiography , Hospitalization , Survivors , Electrolytes
13.
Philippine Journal of Internal Medicine ; : 1-4, 2017.
Article | WPRIM | ID: wpr-960107

ABSTRACT

BACKGROUND: Patients with acute ischemic stroke are susceptible  to  cardiac  arrhythmias  however,fatal arrhythmias  are  rare  in  the  absence  of  cardiac  disease.Cardiac arrhythmias can develop in lesions at the right side of the brain specifically the insular,frontal and parietal area.Data that show the direct relationship of ischemic stroke and arrhythmia are scarce but they are indirectly attributed to an imbalance in the autonomic nervous system.This paper aims to present a rare case of an association between a fatal arrhythmia and right thalamic infarct.   CASE: Presenting a case of a 39-year-old admitted as a survivor of sudden cardiac death from ventricular fibrillation.She presented with a history of left sided weakness a week prior but no work-up was done. Baseline serum electrolytes and  cardiac markers were all normal.Electrocardiogram (ECG) post-cardioversion showed sinus tachycardia.Echocardiogram   and cardiac computed tomography (CT) angiography were normal.  Magnetic resonance imaging (MRI) and angiography (MRA) of the brain showed an acute infarct at the right thalamus and an absent left internal carotid artery (ICA).Electroencephalogram (EEG) was negative.Bisoprolol was given and an Automatic Implantable Cardioverter Defibrillator (AICD) was subsequently placed.No recurrence of cardiac arrhythmia was noted on continuous cardiac telemetry monitoring during her hospitalization and on six months of follow-up.CONCLUSION: Fatal cardiac arrhythmias, can occur in patients with  acute  thalamic  infarct  even  beyond  24  hours  in  the presence of other confounding factors despite the absence of cardiac pathology. This case showed the association of heightened  autonomic  imbalance  caused  by  an  acute stroke, decreased cerebral flow, and fatal arrhythmia. This elucidates the importance of cardiac monitoring in acute ischemic stroke. With the paucity of information on serious cardiac arrhythmia and ischemic stroke, a future study on this correlation will be useful.


Subject(s)
Humans , Female , Adult , Bisoprolol , Tachycardia, Sinus , Ventricular Fibrillation , Carotid Artery, Internal , Defibrillators, Implantable , Electric Countershock , Arrhythmias, Cardiac , Electrocardiography , Death, Sudden, Cardiac , Heart Conduction System , Stroke , Thalamus , Brain , Autonomic Nervous System , Telemetry , Angiography , Hospitalization , Survivors , Electrolytes
15.
Journal of Nutrition and Health ; : 552-564, 2017.
Article in Korean | WPRIM | ID: wpr-182491

ABSTRACT

PURPOSE: The purpose of this study was to measure energy expenditure (EE) the metabolic equivalents (METs) of 13 common physical activities by using a portable telemetry gas exchange system (K4b2) and to assess the accuracy of the accelerometer (Actigraph GT3X+) by gender in Korean adults. METHODS: A total of 109 adults (54 males, 55 females) with normal BMI (body mass index) participated in this study. EE and METs of 13 selected activities were simultaneously measured by the K4b2 portable indirect calorimeter and predicted by the GT3X+ Actigraph accelerometer. The accuracy of the accelerometer was assessed by comparing the predicted with the measured EE and METs. RESULTS: EE (kcal/kg/hr) and METs of treadmill walking (3.2 km/h, 4.8 km/h and 5.6 km/h) and running (6.4 km/h) were significantly higher in female than in male participants (p < 0.05). On the other hand, the accelerometer significantly underestimated the EE and METs for all activities except descending stairs, moderate walking, and fast walking in males as well as descending stairs in females. Low intensity activities had the highest rate of accurate classifications (88.3% in males and 91.3% females), whereas vigorous intensity activities had the lowest rate of accurate classifications (43.6% in males and 27.7% in females). Across all activities, the rate of accurate classification was significantly higher in males than in females (75.2% and 58.3% respectively, p < 0.01). Error between the accelerometer and K4b2 was smaller in males than in females, and EE and METs were more accurately estimated during treadmill activities than other activities in both males and females. CONCLUSION: The accelerometer underestimated EE and METs across various activities in Korean adults. In addition, there appears to be a gender difference in the rate of accurate accelerometer classification of activities according to intensity. Our results indicate the need to develop new accelerometer equations for this population, and gender differences should be considered.


Subject(s)
Adult , Female , Humans , Male , Calorimetry, Indirect , Classification , Energy Metabolism , Hand , Metabolic Equivalent , Motor Activity , Running , Telemetry , Walking
16.
Rev. biol. trop ; 64(4): 1441-1450, oct.-dic. 2016. tab, ilus
Article in English | LILACS | ID: biblio-958225

ABSTRACT

Abstract:Telemetry based on Global Positioning Systems (GPS) makes possible to gather large quantities of information in a very fine scale and work with species that were impossible to study in the past. When working with GPS telemetry, the option of storing data on board could be more desirable than the sole satellite transmitted data, due to the increase in the amount of locations available for analysis. Nonetheless, the uncertainty in the retrieving of the collar unit makes satellite-transmitted technologies something to take into account. Therefore, differences between store-on-board (SoB) and satellite-transmitted (IT) data sets need to be considered. Differences between SoB and IT data collected from two lowland tapirs (Tapirus terrestris), were explored by means of the calculation of home range areas by three different methods: the Minimum Convex Polygon (MCP), the Fixed Kernel Density Estimator (KDE) and the Brownian Bridges (BB). Results showed that SoB and IT data sets for the same individual were similar, with fix ranging from 63 % to 85 % respectively, and 16 m to 17 m horizontal errors. Depending on the total number of locations available for each individual, the home ranges estimated showed differences between 2.7 % and 79.3 %, for the 50 % probability contour and between 9.9 % and 61.8 % for the 95 % probability contour. These differences imply variations in the spatial coincidence of the estimated home ranges. We concluded that the use of IT data is not a good option for the estimation of home range areas if the collar settings have not been designed specifically for this use. Nonetheless, geographical representations of the IT based estimators could be of great help to identify areas of use, besides its assistance to locate the collar for its retrieval at the end of the field season and as a proximate backup when collars disappear. Rev. Biol. Trop. 64 (4): 1441-1450. Epub 2016 December 01.


Resumen:La telemetría basada en los sistemas de geopocisionamiento global (GPS) hace posible recopilar gran cantidad de información a escalas muy finas, y trabajar con especies imposibles de estudiar en el pasado. Al trabajar con telemetría de GPS, la opción de guardar información en la memoria interna del instrumento puede ser más deseable que sólo tener acceso a la información enviada vía satélite, debido a la mayor cantidad de localizaciones disponibles para analizar. No obstante, la incertidumbre de recuperar el collar hace que las tecnología de trasmisión vía satélite deba ser tenida en cuenta. Diferencias entre las bases de datos almacenadas en el collar (SoB) y las trasmitidas vía satélite (IT), recolectadas de dos individuos de Tapir de tierras bajas (Tapirus terrestris), son consideradas, en términos de las áreas de los rangos de hogar calculados con cada uno y mediante el uso de tres metodologías diferentes: Mínimo Polígono Convexo (MCP), Estimador de Densidad de Kernel Fijo (KDE) y los Puentes Brownianos (BB). Las bases de datos SoB e IT son similares, con tasas de acierto de localizaciones que oscilan entre 63 % to 85 % y errores horizontales de 16 m y 17 m respectivamente. Dependiendo del número total de localizaciones disponibles para cada individuo, los rangos de hogar estimados muestran diferencias entre 2.7 % y 79.3 %, para el contorno del 50 % de probabilidades, y entre 9.9 % y 61.8 % para el contorno del 95 % de probabilidades. Estas diferencias implican variaciones en la coincidencia espacial de los rangos de hogar estimados. Concluimos que el uso de la información trasmitida vía satélite no es una buena opción para la estimación de rangos de hogar, si la programción de los collares no ha sido diseñada específicamente para tal fin. Sin embargo, las representaciones geográficas de los estimados a partir de las bases de datos IT pueden ser de gran ayuda para la identificación de áreas de uso, además de su utilidad para la localización y recuperación de collares tras su liberación de los individuos monitoreados y como una base de datos de soporte en caso de pérdida del collar.


Subject(s)
Animals , Male , Female , Perissodactyla , Telemetry/instrumentation , Telemetry/methods , Satellite Communications/instrumentation , Geographic Information Systems/instrumentation , Homing Behavior , Time Factors , Sex Factors , Reproducibility of Results , Colombia , Animal Distribution , Datasets as Topic , Iridium
17.
Braz. j. otorhinolaryngol. (Impr.) ; 82(2): 123-130, Mar.-Apr. 2016. tab, graf
Article in English | LILACS | ID: lil-780987

ABSTRACT

ABSTRACT INTRODUCTION: The cochlear implant device has the capacity to measure the electrically evoked compound action potential of the auditory nerve. The neural response telemetry is used in order to measure the electrically evoked compound action potential of the auditory nerve. OBJECTIVE: To analyze the electrically evoked compound action potential, through the neural response telemetry, in children with bilateral cochlear implants. METHODS: This is an analytical, prospective, longitudinal, historical cohort study. Six children, aged 1-4 years, with bilateral cochlear implant were assessed at five different intervals during their first year of cochlear implant use. RESULTS: There were significant differences in follow-up time (p = 0.0082) and electrode position (p = 0.0019) in the T-NRT measure. There was a significant difference in the interaction between time of follow-up and electrode position (p = 0.0143) when measuring the N1-P1 wave amplitude between the three electrodes at each time of follow-up. CONCLUSION: The electrically evoked compound action potential measurement using neural response telemetry in children with bilateral cochlear implants during the first year of follow-up was effective in demonstrating the synchronized bilateral development of the peripheral auditory pathways in the studied population.


RESUMO INTRODUÇÃO: O implante coclear tem a capacidade de medir o potencial de ação composto eletricamente evocado do nervo auditivo (ECAP). Para esta verificação utiliza-se uma medida chamada telemetria de respostas neurais. OBJETIVO: Analisar o potencial de ação composto evocado eletricamente, por meio da neurotelemetria de respostas neurais, em crianças usuárias de implante coclear bilateral. MÉTODO: Trata-se de um estudo analítico, prospectivo, de coorte histórica longitudinal. Foram recrutadas seis crianças, com idades entre de 1-4 anos, usuárias de implante coclear bilateral. Estas crianças foram avaliadas em cinco momentos durante o primeiro ano de uso do implante coclear. RESULTADOS: Houve diferença significativa no tempo de acompanhamento (p = 0,0082) e posição do eletrodo (p = 0,0019) na medida de T-NRT. Houve diferença significativa na interação entre tempo de acompanhamento e posição do eletrodo (p = 0,0143) na medida da amplitude das ondas N1-P1 entre os três eletrodos a cada tempo de acompanhamento. CONCLUSÃO: A mensuração do ECAP por meio da NRT nas crianças com implante coclear bilateral durante o primeiro ano de acompanhamento foi uma medida importante para apresentar o desenvolvimento bilateral da via auditiva periférica de forma sincronizada nesta população estudada.


Subject(s)
Child, Preschool , Female , Humans , Infant , Male , Cochlear Implants , Cochlear Implantation/rehabilitation , Evoked Potentials, Auditory/physiology , Hearing Loss, Sensorineural/surgery , Action Potentials , Auditory Threshold/physiology , Cochlear Nerve , Prospective Studies , Telemetry
19.
Chinese Journal of Applied Physiology ; (6): 92-96, 2016.
Article in Chinese | WPRIM | ID: wpr-254947

ABSTRACT

<p><b>OBJECTIVE</b>To study the correlation between EEG characteristics of medial prefrontal cortex (mPFC) and drug-seeking behavior of rats with morphine dependent place preference under shuttling condition.</p><p><b>METHODS</b>Forty rats were randomly divided into four groups (n = 10): morphine PL group, NS PL group, morphine IL group and NS IL group. After embeding the electrode in prelimbic (PL) or infralimbic (IL) cortex of each group by brain stereotaxic operation, the model of morphine dependent conditioned place preference (CPP) in rats was established. The differences of EEG wave percentage in mPFC were telemetered and analyzed when rats shuttled before and after the model.</p><p><b>RESULTS</b>After the model, the withdrawal symptoms were evident in morphine PL and IL group, and the activity time and distance in white box were increased obviously. Compared with control group, after the model, the EEG in morphine PL group showed that: when the rats shuttled to white box, 8 wave decreased obviously, P wave increased obviously. When the rats shuttled to black box, brain waves showed opposite changes. The EEG in morphine IL group showed that: when the rats shuttled to white box, a wave increased obviously, P and a wave decreased obviously. When the rats shuttled to black box, the brain wave had no significant differences compared with control group.</p><p><b>CONCLUSION</b>The EEG changes are different in PL and IL cortex of morphine CPP rats under shuttling condition, and the EEG changes are also different when rats shuttling to white or black box. There is possibly different mechanism, when different drug-seeking environmental cues caused EEG changes in different regions of mPFC.</p>


Subject(s)
Animals , Rats , Conditioning, Psychological , Cues , Drug-Seeking Behavior , Electroencephalography , Morphine Dependence , Prefrontal Cortex , Telemetry
SELECTION OF CITATIONS
SEARCH DETAIL